Ask Lasest Price | |
Brand Name : | WIND AUTOMATION |
Model Number : | WIND-DTS-100 |
Price : | Negotiable |
Payment Terms : | T/T |
Delivery Time : | 35 working days |
3Phase Generator Alternator Outside Inside Stator Quality Anayse Testing Machine WIND-DTS-100
Test Items:
1. DC resistance test (include 3 phase balance test,phase equilibrium test)
Test range: 0.001Ω--1000Ω
Test loop: maximum 4 loop (expandable)
Repeat Test accuracy: ≤±0.5%
Test method :Four points,with auto correctting ambient temperature function,
Or Infrared sensor temperature compensation (Optional)
Can eliminate temperature-induced changes in resistance
2. Inductance test
Test range:0.1µH – 999H
Test loop: maximum 4 loop (expandable)
Repeat Test accuracy: ≤±1.0%
Test method :Four points ensure the accuracy
3. Surge test
Pass high voltage between phases
Test condition: AC 100V-3000V adjustable
Pulse peak :0.5msec
Sampling frequency:0 - 20MHz
Test loop: 4 loop
Repeat Test accuracy:< ±2.5%
Judging method:By area difference(Sensitive to inductance and energy loss)
Standard waveform is White,OK waveform is Green, NG waveform is Red
4. Insulation Resistance
Test condition: DC 500V / 1000V
Range: 0.1MΩ~1000MΩ
Tolerance: ±2.5%
5. Hi-pot (Dielectric strength) AC 100-1000V
Testing time:1~10s (0.1s/time)
Range:0.1-20 mA
Tolerance:≤±2.5%
6. Rotation direction test
Clockwise/ Anti-clockwise
Technical Data:
Test item | DC resistance/inductance | Surge | Isolation resistance | Hi-pot |
Para set | 1s/Loop | 1time/Pulse | 1 s/ time | 1s/time |
Test time | 3s | 1s | 1s | 1s |
Cycle Time:
About 6seconds
HS Code:9030390000
Friendly Links: www.everychina.com